  1. product profile 1.1 general description the kma200 is an angle sensor system. the magnetoresistive (mr) element and the mixed signal integrated circuit (ic) are integr ated in one package. this angle system is already pre-programmed, offsets are compensated and therefore, ready to use. via the serial peripheral interface (spi) the kma200 is user programmable. this allows user specific adjustments of the maximum an gle, zero point, clamping level and a 32-bit identifier. the data is stored permanently in an electrically erasable programmable read-only memo ry (eeprom). the device can be programmed to work either in analog or digital (spi) output mode. furthermore, different analog output characteri stics are possible. th e resolution is better than 0.05 ? . the implemented online diagnosis supervises the input and output signals as well as the data processing. deviations and failures of the angle value are indicated in the output signal. overall temperature supervision is implemented. 1.2 features and benefits kma200 programmable angle sensor rev. 8 ? 7 december 2011 product data sheet ? magnetic field angular sensing ? one package angle sensor system ? high accuracy ? resolution better than 0.05 ? ? operating temperature range from ? 40 ? c to +160 ? c ? digital or analog output signals (user programmable) ? online diagnosis ? overvoltage protection at all external pins ? bidirectional digita l interface (spi) ? eeprom (user programmable) ? programmable maximum angle up to 180 ? ? programmable zero point ? pre-calibrated, ready to use device
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 2 of 33 nxp semiconductors kma200 programmable angle sensor 1.3 quick reference data [1] diagnosis gnd and v dd lost only possible with a pull-up resistor of 5 k ? to 6 k ? . [2] diagnosis v dd lost only possible with a pull-down resistor of 5 k ? to 6 k ? . [3] load resistor required to enable the diagnosis features. infinite resistor load permitted fo r normal operation without the d iagnosis features. 2. pinning information [1] the other pins and lead frame parts must not be el ectrical connected. for ope ration of the device the external pins must/have to be used. 3. ordering information table 1. quick reference data symbol parameter conditions min typ max unit v dd supply voltage normal operation 4.5 5.0 5.5 v v dd(pr) programming supply voltage eeprom 12 12.5 13 v t amb ambient temperature < 1000 hours in life time at 160 ?c ? 40 - +160 ?c t amb(pr) programming ambient temperature eeprom 10 - 70 ?c c l load capacitance at pin 2 and pin 3 0.1 - 27 nf r l(pu) pull-up load resistance [1] 5- ? k? r l(pd) pull-down load resistance [2] [3] 5- 10k ? c ext external capacitance between v dd and gnd conducted closely to supply pins of kma200 82 - 120 nf table 2. pinning pin symbol description simplified outline [1] 1v dd supply voltage 2 data/out1 data input/output (i/o) analog output 1 3 clk/out2 data clock analog output 2 4 gnd ground 5cs chip select (used for data transfer i/o) 12345 table 3. ordering information type number package name description version kma200 - plastic single-ended multi-chip package; 6 interconnections; 5 in-line leads sot637
xxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx x xxxxxxxxxxxxxx xxxxxxxxxx xxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxx xx xxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxx xxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxx xxxxxxxxxxxxxx xxxxxx xx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxx xxxxx x x kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 3 of 33 nxp semiconductors kma200 programmable angle sensor 4. functional diagram fig 1. functional diagram cosine bridge mr-sensor element sine bridge instr.- amp. buffer 1 misc diagnostics digital part ? -modulator ? 006aaa296 bias +1 counter dec.-fil. calibration microcontroller + / ? /and/or osc, oscfs temp. sensor v ref aux. adc reverse polarity protection over-voltage and reverse polarity protection voltage limiter serial interface watchdog- timer eeprom rom hv- protection buffer 2 h(z) instr.- amp. ? -modulator resistor- string d/a ? analog output stage analog input stage h(z) dec.-fil. cs gnd data/out1 clk/out2 v dd
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 4 of 33 nxp semiconductors kma200 programmable angle sensor 5. functional description the kma200 amplifies two orthogonal sinusoidal signals delivered by the mr-sensor element and converts them into the digital domain. using the coordinate rotation digital computer (cordic) algorithm, the angle is ca lculated. angle output is either analog or digital. the kma200 comprises diagnostic features that ensure a complete online supervision of all essential fu nctional blocks including verification of input and output signals and temperature supervision. in additi on, the circuit is prot ected against reverse polarity, overvoltage and short circuit at all external pins. two instrumentation amplifiers and ?? -modulators convert the amplified signals into two high-speed digital bit streams. the bit stream s are filtered and decimated by two digital decimation filters to obtain digital sign als with higher resolution at a lower speed. further processing is done within an on-chip calibration microcontroller. this includes offset cancellation, calculation of the me chanical angle using the cordic algorithm, zero-angle and angular-range adjustment. in addition, the calibration micr ocontroller performs diagnostic tasks to ensure the validity of its results. the calibration microcontroller takes calibration constants from an on-chip eeprom and stores intermediate results in a random access memory (ram). the calculated angle is given out either digitally with an spi-compatible serial interface or analog via the analog output stage. several output characteristic s can be selected. in case of analog output the analog output stage is used for conversion of the angle information into two analog output voltages ratiometric to the supply voltages. for this purpose, the analog output stage contains tw o resistor-string digital-to-analog converters (dacs) which share the same resistor string. the two analog output voltages are buffered by two offset-compensated amplifiers. the internal circuitry is protected against overvoltage with special protection circuits. protection against reverse polarity is realized with the help of a current limiting circuit. in addition, there are various su pport circuits like bias genera tors, a free-run ning oscillator including an oscillator fail-safe circuit and a power-on reset circuit which generates a reset in dependence of the supply voltage.
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 5 of 33 nxp semiconductors kma200 programmable angle sensor 6. diagnostic features the kma200 includes diagnostic features to ens ure the validity of its output signals. the diagnostic features can be configured with the control information word s (ctrl) written to the user-programmable eeprom. in the analog output modes a diagnostic error c ondition is signaled to the user by setting the outputs into the high-impedance state. the outputs are forced to lie in the upper or lower diagnostic range by external pull-up or pull-down resistors. with no external pull-up/pull-down resistors the output signal will be in ternally pulled up to upper diagnosis range. if digital output is selected, an error condition can also be signaled by setting the error flag in the digital output word. the least significant bits show the error code. the ta b l e 4 shows the behavior in detail: once a diagnostic error condition is reache d, the kma200 continues to work normally after a new external power-on reset or by itself, as described in the table below. it is possible to configure the kma2 00 the way that the error condition has to be fulfilled more than once. the number of error conditions that is necessary can also be programmed with bits in the control information words. [1] reactivation for angular measurement with valid angle information (normal operation mode) only by new external power-on reset temperature supervision the chip temperature measured within the kma200 can be used to detect over-temperature conditions. two temperature levels are defined: the temperature warning level and the temperature shutdown level. the user can evaluate the temperature warning if digital output mode is selected. when the device temperature exceeds the warning level, the error flag in the digital output word is set. the other data bits st ill show the angle info rmation. in the analog output modes, the device temperature warning is not available. if the temperature exceeds the over-temperature shutdown level, the kma200 switches off. table 4. summary kma200 behavior at diagno sis conditions in normal operation mode error appearance analog output digital output oscillator fail detection [1] high-impedance state [1] high-impedance state cyclic redundancy check (crc) [1] high-impedance state [1] diagnosis bit set watchdog [1] high-impedance state [1] high-impedance state input stage (including magnet lost) hi gh-impedance state diagnosis bit set output stage [1] high-impedance state - over-temperature warn ing - diagnosis bit set over-temperature shutdown [1] high-impedance state [1] high-impedance state overvoltage high-impedance state high-impedance state reverse polarity high-impedance state high-impedance state
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 6 of 33 nxp semiconductors kma200 programmable angle sensor diagnosis of input stage for diagnosis of the input stage, the calibration microcontroller calculates the expected signal magnitude using the temperature information and the eeprom constants and compares it to the signal magnit ude based on the current measurement. if the difference of the two magnitudes is greater than an allowed deviation, an error condition is signaled to the user. the allowed difference de pends on the bits di1 and di0 in the eeprom control information word. diagnosis of output stage both analog outputs are supe rvised by the auxiliary adc which reads the present analog signal and converts it back to the digital domain with a resolution of 8 bits. the digitized value is compared to the digital angle value originally sent. if the difference of these two values is greater than an error bound, an error condition is signaled by switching off the analog outputs. the allowed difference depends on the bits do1 and do0 in the eeprom control information word. crc check of eeprom constants during normal operation mode a crc code of the configuration constants taken from the eeprom is calculated on a regular basis. this code is compared to a pre-calculated crc code from the eeprom (crc). if there is a mi smatch, an error condi tion is signaled to the user by setting the error flag in the digita l output word or by switching off the analog outputs. the crc code used is the crc-16 code ( iso/iec 3309:1993 and itu-t v.42 ) watchdog timer the kma200 comprises a watchdog timer to supervise the flow of the program. after reset, the watchdog is automatically activated. during op eration the watchdog timer must be toggled on a regular basis, as otherwise t he error condition is signaled. the access to the watchdog timer is protected against unwanted operations using a fail-safe watchdog feed sequence.
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 7 of 33 nxp semiconductors kma200 programmable angle sensor oscillator fail- safe circuit the function of the free-running oscillator is checked with re-triggered mono flop. if the mono flop is not triggered, the kma200 signals an error. fig 2. power supply behavior; the device operation dependencies to its power supply voltage 006aaa297 high overvoltage protection low overvoltage protection operation low voltage reverse polarity protection power on/off reset undefined 32 v 26.5 v 13 v 12 v 7 v 5.5 v 4.5 v 3.1 v 4.45 v 2.9 v 4.4 v 6 v 0 v ?16.5 v device damage normal operation area specification parameters are not valid (*) (diagnosis functions available) 0.05 v < hysteresis< 0.6 v switch-on switch-off overvoltage protection for 400 ms overvoltage protection for infinite duration overvoltage protection, normal programming area, temp within 0 c to 70 c overvoltage protection, programming area - unsufficient voltage specification parameters are not valid (*) (diagnosis functions available) low voltage (device switched-off) reverse polarity voltage protection device damage reset reset reset off off undefined operating weak pull-up operating operating device situation modes v dd
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 8 of 33 nxp semiconductors kma200 programmable angle sensor 7. outputs of kma200 the output of the kma200 is either digital or analog, depending on the control word stored in the eeprom. the analog output consists of a standard and a programmable output stage. the programmable output stage allows four different characteristics; mode 1, mode 2, mode 3 or none output. the digital output has two different modes; mode 5 and mode 6. analog output in the analog output mode the measured angle value is converted linear into a value that is ratiometric to the supply voltage v dd . this voltage is driven by the standard output stage to pin data/out1. the same value is fed to a second output stage that is connected to pin clk/out2. this second output stage is programmable to one of four different output characteristic s; mode 1, mode 2, mode 3 or high-impedance state output. a valid angle value is nominally mapped to an output voltage range of v (cl)l (default = 5 %) to v (cl)u (default = 95 %) of v dd at the standard output v out1 (see figure 3 ). for mode 1 the valid output voltage range at pin clk/out2 is identical to the output voltage range of the standard analog voltage but the output characteristic is inverted (see figure 4 ). in mode 2 (see figure 5 ) the valid output range at pin clk/out2 is nominally v (cl)l /2 to v (cl)u /2 of v dd . a further possibility is to program the v out2 (mode 3, ? thresh ) as a comparator depending from the angle value (see figure 6 ). when the kma200 detects an error condition, it switches the analog outputs into high-impedance state. the outputs are forced to lie in the upper or lower diagnostic range by the external pull-up or pull-down resistors. table 5. setting the kma200 output characteristics output characteristics pin assignment mode setting of eeprom (ctrl1) mode type data/out1 clk/out2 om2 om1 om0 mode 1 analog standard inverted 1 0 0 mode 2 analog standard half range 1 0 1 mode 3 analog standard comparator 1 1 0 mode 4 analog standard high-impedance state 1 1 1 mode 5 digital serial data (spi) (clock) 0 0 0 mode 6 digital bit complement serial data (spi) (clock) 001
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 9 of 33 nxp semiconductors kma200 programmable angle sensor fig 3. standard analog output mode fig 4. inverted analog output (mode 1) 006aaa298 0 180 max 100 % 96 % v (cl)u v (cl)l 4 % 0 v out1 / v dd diagnostics area diagnostics area (180 ? max ) / 2 006aaa299 0 180 max 100 % 96 % v (cl)u v (cl)l 4 % 0 v out2 / v dd diagnostics area diagnostics area (180 ? max ) / 2
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 10 of 33 nxp semiconductors kma200 programmable angle sensor fig 5. half range output mode (mode 2) fig 6. comparator analog output (mode 3) 006aaa300 0 180 max 100 % 50 % v (cl)u /2 v (cl)l /2 2 % 0 v out2 /v dd diagnostics area diagnostics area (180 ? max )/2 006aaa301 0 180 (180 ? max ) / 2 max thresh 100 % 90 % 10 % 0 v out2 / v dd v out1 v out2 high low
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 11 of 33 nxp semiconductors kma200 programmable angle sensor 8. digital output (spi) standard digital output if the standard digital output mode is configur ed, output data can be read with the serial interface. figure 7 shows the timing diagram of an interface access. the access is enclosed by a high-to-low and low-to-high transition of cs . data are clocked out at the falling edge of clk and should be evaluated at the rising edge. the output data consist of 3 bytes (24 bit s). the first two data bytes contain an error flag and 13 bits of angle information. th e last data byte contains the measured temperature as 7-bit value. every byte features a parity bit (odd parity). the data transmission can be interrupted at any time by deactivating cs . if, for instance, the temperature information is not desired, the data transfer can be finished by deactivating cs after reading the first two data bytes. if the error flag is 0, the 13 angle data bits contain the most significant bits of the calculated angle. if the error flag is 1, an error condition was detected. the two least significant angle data bits (a[1:0]) are replaced by an error code. all other angle data bits (a[12:2]) still show the current measurement va lue. depending on th e special error case, the measurement values are reliable or not. error codes are described in ta b l e 8 . the output driver of the data pin is slew-rat e limited. the rise and fall times of the data output can be programmed with the sl bit (ctrl eeprom constant); see table 12 . complementary digital output in complementary digital output mode the data tr ansmitted is identical to the output data in standard digital output mode except that th e angle and temperature information data bits are logically inverted. the error flag and the error code in bits a[1:0] when the error flag is set are coded as in case of standard digital output. the parity bits also use odd parity as standard digital output mode. fig 7. digital output coding 006aaa302 cs clk data angle (msbs) angle (lsbs) temperature data high-z (high by internal weak pullup) parity bits (odd parity) error flag 13-bit angle data 7-bit temperature data p2, p1, p0 ef a12 to a0 t6 to t0 p2 a12 a11 ef a7 a6 a5 p1 a0 t6 t5 p0 t0
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 12 of 33 nxp semiconductors kma200 programmable angle sensor 9. limiting values table 6. limiting values in accordance with the absolute ma ximum rating system (iec 60134). symbol parameter conditions min max unit v dd supply voltage pin v dd versus gnd ? 16.5 +26.5 v at t < 400 ms - 32 v v x voltage on pins cs , data/out1, clk/out2 versus gnd 0100%v dd t amb ambient temperature < 1000 hours in life time at 160 ?c ? 40 +160 ?c t amb(pr) programming am bient temperature eeprom 10 70 ?c t stg storage temperature ? 50 +150 ?c eeprom t ret retention time t max(av) =50 ?c1 7 - y e a r n endu(w_er) write or erase endurance t max(av) =70 ? c for programming - 500 cycle
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 13 of 33 nxp semiconductors kma200 programmable angle sensor 10. characteristics table 7. characteristics in homogenous magnetic field at saturation field streng th of minimum 35 ka/m and external capacitance c ext between v dd and gnd. t amb = ? 40 ? c to +160 ? c; v dd = 4.5 v to 5.5 v. symbol parameter conditions min typ max unit supply voltage and operation currents v dd supply voltage normal operation 4.5 5.0 5.5 v v dd(pr) programming supply voltage eeprom 12 12.5 13 v i dd supply current for normal operation mode 5 - 12 ma c l load capacitance at pin 2 and pin 3 0.1 - 27 nf r l(pu) pull-up load resistance [1] 5- ? k? r l(pd) pull-down load resistance [2] [3] 5-10k ? c ext external capacitance between v dd and gnd conducted closely to supply pins of kma200 82 - 120 nf power-on reset v ddon switch-on threshold voltag e kma200 switches on if v dd >v ddon 3.1 3.75 4.45 v v ddoff switch-off threshold voltag e kma200 switches off if v dd kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 14 of 33 nxp semiconductors kma200 programmable angle sensor analog programmable output v out2 : mode 1 v out2(nom) nominal output voltage range on pin out2 5-95%v dd v o(ldr) lower diagnostic range output voltage on out2 0 - 4 %v dd v o(udr) upper diagnostic range output voltage on out2 96 - 100 %v dd ? max maximum angle programmable from 0 ? to angle range ? max eeprom address 3 0.1 - 180 deg v (cl)u upper clamping voltage level setti ng by eeprom address 9 69.5 - 95 %v dd v (cl)l lower clamping voltage level setting by eeprom address 9 5 - 30.5 %v dd ? res angle resolution 4608 counts in nominal output voltage range (clamping level 5%v dd to 95 %v dd ) [4] - 0.04 0.05 deg n o output noise peak to peak, 25 ms measurement time [4] - - 0.1 deg ? v (cl) clamping voltage variation at 5 %v dd and 95 %v dd [4] ? 0.3 - +0.3 %v dd ?? lin angle linearity error normal operation mode, deviation from reference line [4] ? 1.65 - +1.65 deg ?? t angle temperature drift valid for temperature range ? 25 ?c up to +125 ? c (3 sigma) [4] [5] ? 0.64 - +0.64 deg ?? ? lin microlinearity deviation at an angle step of 1 ? [4] ? 0.1 - +0.1 deg ?? hys hysteresis absolute value [4] 0 - 0.088 deg v pl(mode1) plausibility v out1 to v out2 (mode 1) ?v out1 +v out2 ? v dd ?? v pl(mode1) [4] ? 0.5 - +0.5 %v dd table 7. characteristics ?continued in homogenous magnetic field at saturation field streng th of minimum 35 ka/m and external capacitance c ext between v dd and gnd. t amb = ? 40 ? c to +160 ? c; v dd = 4.5 v to 5.5 v. symbol parameter conditions min typ max unit
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 15 of 33 nxp semiconductors kma200 programmable angle sensor analog programmable output v out2 : mode 2 v out2(nom) nominal output voltage range on pin out2 2.5 - 47.5 %v dd v o(ldr) lower diagnostic range output voltage on out2 0 - 2 %v dd v o(udr) upper diagnostic range output voltage on out2 50 - 100 %v dd ? res angle resolution 2304 counts in nominal output voltage range with clamping level 5%v dd to 95 %v dd [4] -0.08-deg ? max maximum angle programmable from 0 ? to angle range ? max eeprom address 3 0.1 - 180 deg n o output noise peak to peak, 25 ms measurement time [4] - - 0.2 deg ? v (cl) clamping voltage variation at 2.5 %v dd and 47.5 %v dd [4] ? 0.3 - +0.3 %v dd ?? lin angle linearity error normal operation mode, deviation from reference line [4] ? 2.0 - +2.0 deg ?? t angle temperature drift valid for temperature range ? 25 ?c up to +125 ? c (3 sigma) [4] [5] ? 0.64 - +0.64 deg ?? ? lin microlinearity deviation at an angle step of 1 ? [4] ? 0.2 - +0.2 deg ?? hys hysteresis absolute value [4] 0 - 0.088 deg v pl(mode2) plausibility v out1 to v out2 (mode 2) ?v out1 ? 2 ? v out2 ?? v pl(mode2) ? 0.7 - +0.7 %v dd analog programmable output v out2 : mode 3 v out2(l) low-level output voltage on pin out2 0-10%v dd v out2(h) high-level output voltage on pin out2 90 - 100 %v dd ? th(res) threshold angle resolution setti ng by eeprom address 4 - - 16 bit digital output and complement digital output ? res(dig) digital angle resolution - 0.022 - deg/lsb n dig digital noise level noise: 10 measurements in sequence --4lsb ?? lin angle linearity error normal operation mode from reference line ? 1.65 - +1.65 deg ?? t angle temperature drift ? 1.3 - +1.3 deg valid for temperature range ? 25 ?c up to +125 ? c (3 sigma) ? 0.5 - +0.5 deg ?? ? lin microlinearity ? 0.088 - +0.088 deg ?? hys hysteresis absolute value 0 - 0.088 deg table 7. characteristics ?continued in homogenous magnetic field at saturation field streng th of minimum 35 ka/m and external capacitance c ext between v dd and gnd. t amb = ? 40 ? c to +160 ? c; v dd = 4.5 v to 5.5 v. symbol parameter conditions min typ max unit
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 16 of 33 nxp semiconductors kma200 programmable angle sensor [1] diagnosis gnd and v dd lost only possible with a pull-up resistor of 5 k ? to 6 k ? . [2] diagnosis v dd lost only possible with a pull-down resistor of 5 k ? to 6 k ? . [3] load resistor required to enable the diagnosis features. infinite resistor load permitted fo r normal operation without the d iagnosis features. [4] analog outputs need to be low-pass fi ltered (corner frequency about 1.3 khz). [5] see figure 9 . on-chip temperature sensor characteristics t sen sensor temperature chip temperature ? 50 - +180 ?c t sen(res) sensor temperature resolution chip temperature - 2 - ?c/lsb ? t sen sensor temperature accuracy chip temperature ? 5- +5 ?c t warn(res) warning temperature resolution setting by eeprom address 6 - 2 - ?c t shut(res) shut-down temperature resolution setting by eeprom address 6 - 2 - ?c spi characteristics v il low-level input voltage for v x =clk, cs , data 0 - 25 %v dd v ih high-level input voltage for v x =clk, cs , data 75 - 100 %v dd v ol low-level output voltage i sink <2ma 0 - 15 %v dd v oh high-level output voltage i source <2ma 85 - 100 %v dd i om peak output current current limitation of the device - - 20 ma t r(o) output rise time normal operation mode from 10 %v dd to 90 %v dd , c l = 100 pf (sl bit = 0) 100 - 400 ns (sl bit = 1) 500 - 1300 ns t f(o) output fall time (sl bit = 0) 100 - 400 ns (sl bit = 1) 500 - 1300 ns f clk clock frequency for v x = clk 1 - 1000 khz dynamics t pu power-up time until first valid result - - 10 ms f upd(meas) measurement update rate at oscillator frequency 3 4 5 khz t s settling time after ideal input angle step until analog standard output reaches 90 % of final value, at nominal oscillator frequency, c l =5nf -11.8ms table 7. characteristics ?continued in homogenous magnetic field at saturation field streng th of minimum 35 ka/m and external capacitance c ext between v dd and gnd. t amb = ? 40 ? c to +160 ? c; v dd = 4.5 v to 5.5 v. symbol parameter conditions min typ max unit
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 17 of 33 nxp semiconductors kma200 programmable angle sensor 11. error codes standard digital output: (1) temperature = ? 50 ? c + t[6:0] ? 2 ? c complement digital output: (2) temperature = ? 50 ? c+t [6:0] ? 2 ? c table 8. error codes a[1:0] description angle valid 00 diagnosis error no 01 diagnosis error (input stage) no 10 over-temperature warning yes 11 (not occupied) - a a[12:0] 180 ? 2 13 ----------- a[12:0] 0 . 022 ???? = a a[12:0] 180 ? 2 13 ----------- ? a[12:0] 0 . 022 ??? =
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 18 of 33 nxp semiconductors kma200 programmable angle sensor 12. definition of errors 12.1 general for the accuracy is assumed th at the sensor operates in a homogeneous magnetic field at saturation field strength h sat . also, the zero angle register of the kma200 is set at a mechanical reference point at room temperature (and zero degree). this reference line is valid for digital and analog outputs. the maximum angle is set to 180 ? and the clamping levels are programmed to v (cl)l = 5 %v dd and v (cl)u =95%v dd . 12.2 linearity error the deviation from the reference line ?? lin is called angle linearity error and defined as follows: ?? lin = ? lin ( ? ref ,t j ) ?? ref t j : any ambient temperature in the specific range following formula is used to calculate ? meas in degree from an analog voltage value: (3) v out : analog output of kma200 [%v dd ] for sensors the error of the analog output ?? lin is only defined in the range from 5.5 %v dd to 94.5 %v dd . ? ref : reference angle in degree ? meas : measured angle of the kma200 in degree ?? lin : deviation from reference line in degree fig 8. visualization of linearity behavior 006aaa303 180 180 output reference line 0 ? meas () ? ref () ? lin ? meas v out 5 %v dd ? 95 %v dd 5 %v dd ? -------------------------------------------------- 180 ?? =
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 19 of 33 nxp semiconductors kma200 programmable angle sensor 12.3 temperature drift the temperature drift is defined as the enve lope deviation of the angle value over the temperature range. it is considered as the pure thermal effect. following mathematical description is given for temperature drift value: ?? t = ? meas ( ? ref ,t j ) ?? meas ( ? ref ,t k ) ?? : temperature drift, deviation over temperature in degree ?? lin : linearity error measured at different temperatures in degree t j , t k and t m : any ambient temperature in the specified range (t amb ) fig 9. temperature drift behavior 006aaa304 temperature t m temperature t k temperature t j ? ref () ? t ? lin ()
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 20 of 33 nxp semiconductors kma200 programmable angle sensor 12.4 microlinearity microlinearity is the deviation between the device output and the reference line at any angle and for an angle step of 1 ? . the microlinearity is determined at a constant temperature. the microlinearity is calculated as follows: ?? ?lin =v meas ( ? ref(i+1) ) ? v ideal ( ? ref(i+1) ) v ideal ( ? ref(i+1) )=v meas ( ? ref(i) )+m ideal ? 1 ? =v meas ( ? ref(i) )+0.5%v dd ?? ?lin : microlinearity v meas ( ? ref(i) ): measured voltage [%v dd ] for angle position ? ref(i) m ideal : ideal, theoretical slope; with 90 %v dd and maximum angle 180 ? the output slopes are monotonic by design. this figures can also be used for the definition of ?? ?lin in digital mode, as follows: assume that v meas ( ? ref(i) )= ? meas ( ? ref(i) ) and v meas ( ? ref(i+1) )= ? meas ( ? ref(i+1) ), whereas ? meas (x) is the output angle of the kma200 at the angle position x. fig 10. microlinearity behavior 006aaa305 voltage v meas ( ? ref(i +1) ) v ideal ( ? ref(i +1) ) v meas ( ? ref(i) ) theoretical slope m ideal starting at output v meas ( ? ref(i) ) ? ref = 1 = | ? ref(i) ? ? ref(i +1) | angle ? lin
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 21 of 33 nxp semiconductors kma200 programmable angle sensor 12.5 hysteresis the hysteresis error is defined as the maximum difference between angle values given by the device output when performing a positive (clockwise) rotation and negative rotation (counter clockwise) over an angle range of 180 ? . the hysteresis error is defined as follows: ?? hys = ?? meas cw( ? ref ) ?? meas ccw( ? ref ) ? ?? hys : hysteresis ? meas : cw measured angle for clockwise rotation ? meas : ccw measured angle for counter clockwise rotation 13. programming the kma200 comprises two major modes of operation. these modes are: 13.1 normal operation mode this is the default mode. the kma200 starts in this mode without th e need of writing to the serial interface. in this mode a contin uous conversion of the input signals into the corresponding angles takes place. this mode is configured with the on-chip eeprom. once in normal operation mode, the kma200 can be reactivated for command mode only by a new power-on reset. fig 11. hysteresis 006aaa306 180 180 ? meas () ? ref () ? hys
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 22 of 33 nxp semiconductors kma200 programmable angle sensor 13.2 command mode this mode is used for calibration and programm ing. the kma200 is co ntrolled with serial interface commands. to activate the command mode, the following initialization procedure must be executed during power-on reset. the pin cs must be constantly held on high level and pin clk/out2 must be constantly held on low level during power-on. this condition has to start during reset and must be valid duri ng the following initialization phase of the kma200 for at least 1 ms. cs and clk are interna lly weak pull-up so that at least clk must be actively driven. if these conditions are valid, the kma200 starts in command mode. at all other combinations or if the levels are not cons tant for the minimum time of 1 ms, the kma200 starts in normal operation mode. the normal operation mode is configured with sixteen 16-bit constants stored in the on-chip eeprom. 13.3 notes to the programming the kma200 sensor is delivered in a pre-calibrated and preprogrammed default condition. the eeprom addresses 0, 1, 5, c, d and e are device dependent and pre-calibrated for each device. a changing of this contents to another value is not allowed, because the specified data, influenced by these addresses, are no longer valid. the eeprom addresses a and b are used to store production related information. a changing of these values should not be done. definition: address a: storage the date code. date code assembly center: day of the year (maximum 365) + year (maximum 99) fig 12. command mode 006aaa307 cs max. 3 ms min. 1 ms (asic internal power-on-reset) data/out1 clk/out2 v dd
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 23 of 33 nxp semiconductors kma200 programmable angle sensor address b: storage the assembly lot no. (maximum 65535) 13.4 write ram (0nh), read ram (1nh) to write data to the ram the command byte 0nh (n is the address of the data) followed by the 16-bit data has to be send. to read data from the ram, the command byte 1nh has to be send. if cs is activated again, the ram contents at the specified address is clocked out. note that at po wer-on addresses 00h to 0fh are read from the eeprom into the ram. 13.5 calculate crc-16 and program eeprom (30h) to program the eeprom, the configuration data has to be wr itten to the ram addresses 00h to 0eh. afterwards, the command by te 30h has to be sent and the eeprom programming voltage has to be applied at the v dd pin. the kma200 calculates the crc-16 check sum and writes the ram constants at addresses 00h to 0fh to the eeprom. this command is only executed when the ep bit in th e control info rmation word is logic 0 on power-on. if the ep bi t is logic 1, this command is ignored. table 9. eeprom content address name description 0 sensor_offset_1 dependent of individual production calibration results 1 sensor_offset_2 dependent of individual production calibration results 2 zero_angle mechanical 0 ? position relative to the zero point of the sensor output; used for zero-angle calibration default value: 0000h (0 ?) 3 angular_range definition of the angular input range that is mapped to the whole analog output signal range default value: 0000h (180 ?) 4 ? thresh threshold for programmable output in mode 3 default value: internal crc of the addresses 0, 1, 5, c, d and e 5 temp_vref, temp_offs dependent of individual production calibration results 6t shut(res) , t warn(res) temperature warning and temperature shutdown level; used for temperature supervision default value: faf8h (temperature shutdown at 200 ? c, warning at 198 ?c) 7 ctrl1 control informati on word 1; used for selection of various operating modes default value: 4046h (output mode standard + mode 1) 8 ctrl2 control information word 2; configures the diagnostic functions default value: 0704h (temperature supervision is on; input stage diagnosis is on; output stage diagnosis is off) 9v (cl)l , v (cl)u clamping voltage levels of analog outputs default value: 00ffh (clamping level low at 5 %v dd , clamping level high at 95 %v dd ) a id1 sensor identifier 1; this data is not evaluated by the kma200 and is used for sensor identification b id2 sensor identifier 2; this data is not evaluated by the kma200 and is used for sensor identification c anom, tc_anom dependent of individual production calibration results
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 24 of 33 nxp semiconductors kma200 programmable angle sensor [1] ep: eeprom write protection: default value: 0 0 ? eeprom programming possible 1 ? eeprom not writable this bit is evaluated only if the crc checksum is valid. [2] sl: rise and fall time of data output: default value: 0 0 ? nominal 150 ns 1 ? nominal 750 ns [3] do[1:0]: diagnosis of output stage: default value: 00 00 ? level 0: ? v meas(out) ? v exp(out) ? <10%v dd 01 ? level 1: ? v meas(out) ? v exp(out) ? <5%v dd 10 ? level 2: ? v meas(out) ? v exp(out) ? <2%v dd 11 ? level 3: ? v meas(out) ? v exp(out) ? <1%v dd [4] di[2:0]: diagnosis of input stage: default value: 000 000 ? level 0: ? a meas ? a soll ? <6.24mv/v 001 ? level 1: ? a meas ? a soll ? <4.68mv/v 010 ? level 2: ? a meas ? a soll ? <3.12mv/v 011 ? level 3: ? a meas ? a soll ? <1.56mv/v 100 ? level 4: ? a meas ? a soll ? <0.78mv/v [5] om[2:0]: output mode: default value: 100 000 ? digital output 001 ? complement digital output 100 ? analog output; standard + programmable output mode 1 101 ? analog output; standard + programmable output mode 2 110 ? analog output; standard + programmable output mode 3 111 ? analog output; standard output only d tc_offset_1 dependent of individual production calibration results e tc_offset_2 dependent of individual production calibration results f crc-16 dependent of individual programming table 9. eeprom content ?continued address name description table 10. format of zero_angle, angular_range and ? thresh zero_angle = a[15:0] ? 0.00275 ? , angular_range = a[15:0] ? 0.00275 ? and ? thresh = a[15:0] ? 0.00275 ? . msb lsb 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 a[15] a[14] a[13] a[12] a[11] a[10] a[9] a[ 8] a[7] a[6] a[5] a[4] a[3] a[2] a[1] a[0] table 11. format of t shut(res) and t warn(res) t shut(res) = ? 50 ? c + ts[7:0] ? 1 ? c and t warn(res) = ? 50 ? c+tw[7:0] ? 1 ? c. msb lsb 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 t shut(res) t warn(res) ts [7] ts [6] ts [5] ts [4] ts [3] ts [2] ts [1] ts [0] tw [7] tw [6] tw [5] tw [4] tw [3] tw [2] tw [1] tw [0] table 12. format of ctrl1 msb lsb 15 14 13 [1] 12 11 [2] 10 [3] 9 [3] 8 [4] 7 [4] 6 [5] 5 [5] 4 [5] 3 2 1 0 0 1 ep 0 sl do1 do0 di1 di0 om2 om1 om0 0 1 1 0
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 25 of 33 nxp semiconductors kma200 programmable angle sensor [1] di[2:0]: diagnosis of input stage: default value: 000 000 ? level 0: ? a meas ? a soll ? <6.24mv/v 001 ? level 1: ? a meas ? a soll ? <4.68mv/v 010 ? level 2: ? a meas ? a soll ? <3.12mv/v 011 ? level 3: ? a meas ? a soll ? <1.56mv/v 100 ? level 4: ? a meas ? a soll ? <0.78mv/v [2] fb: automatic fallback into normal operation mode: default value: 1 0 ? disabled 1 ? enabled this bit is evaluated only if the crc checksum is valid. [3] ets: enable temperature supervision: default value: 1 0 ? disabled 1 ? enabled [4] tc[1:0]: error counter temperature supervision: default value: 00 00 ? 0 01 ? 2 10 ? 4 11 ? 8 [5] edo: enable diagnosis output stage: default value: 0 0 ? disabled 1 ? enabled [6] co[1:0]: error counter diagnosis output stage: default value: 00 00 ? 0 01 ? 2 10 ? 4 11 ? 8 [7] edi: enable diagnosis input stage: default value: 1 0 ? disabled 1 ? enabled [8] ci[1:0]: error counter diagnosis input stage: default value: 00 00 ? 0 01 ? 2 10 ? 4 11 ? 8 table 13. format of ctrl2 msb lsb 15 14 13 12 11 [1] 10 9 [2] 8 [3] 7 [4] 6 [4] 5 [5] 4 [6] 3 [6] 2 [7] 1 [8] 0 [8] 0 0 0 0 di2 1 fb ets tc1 tc0 edo co1 co0 edi ci1 ci0 table 14. format of v (cl)l and v (cl)u lower clamping level output voltage = 5 %v dd +v (cl)l ? 0.1 %v dd and upper clamping level output voltage = 69.5 %v dd +v (cl)u ? 0.1 %v dd . msb lsb 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 v (cl)l v (cl)u 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 26 of 33 nxp semiconductors kma200 programmable angle sensor 14. electromagnetic interference (emi) the following tests are performed with the sensor system kma200. details of the measurements and behavior are available on request. 14.1 emission (cispr 25) conducted radio disturbance: tests accordin g cispr 25, chapter 11 (artificial network). radiated radio disturbance: test according cispr 25, chapter 13 (anechoic chamber - component/module). 14.2 radiated disturbances (iso 11452-2, iso 11452-5) immunity against mobile phones and absorber lined chamber and strip line (alcs); strip line measurements are performed up to 1 ghz. 14.3 transients - pulses (iso 7637-1, iso 7637-3) galvanic: line conducted pulses on the supply lines according iso 7637-1 pulses 1, 2, 3a, 3b, 4 and 5 (for pulse no. 5 a suitab le protection circuit must be used). coupled: transient transmission by capacitive and inductive coupling via lines other than supply lines (interface, analog output) according iso 7637-3 pulses 3a and 3b. 15. electrostatic discharge (esd) 15.1 human body model the kma200 must not be damaged at 4000 v, 100 pf, 1.5 k ? to the human body model. the test is according to mil-std-883d meth od 3015.7. this protec tion must be ensured at all external pins (clk/out2, cs and data/out1) including device supply (v dd , gnd). for the interconnects (pins between upper and lower package part), the protection is up to 1500 v. 15.2 machine model the kma200 must not be damaged at 400 v to the machine model. the test is according to mil-std-883d method 3015.7. this protection must be ensured at all external pins (clk/out2, cs and data/out1) including device supply (v dd , gnd). for the interconnects (pins between upper and lower package part), the protection is up to 100 v. 16. terminals device terminals shall be compatible wit h laser welding and electrical welding. lead frame material: cuzr with 0.1 % zr, 99.9 % cu lead finish: pure tin, 7 ? m ? thickness ? 11 ? m
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 27 of 33 nxp semiconductors kma200 programmable angle sensor 17. marking package is sot637 marking paint: laser on package head and package body letter height: 0.8 mm marking of package head: batch number marking of package body: type no., date code (x yyy z); x: m for manufacturing manila, y: day of the year, z: year of production
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 28 of 33 nxp semiconductors kma200 programmable angle sensor 18. package outline fig 13. package outline sot637 unit b p c v l 2 min. references outline version european projection issue date iec jedec jeita mm 1.65 1.45 0.41 0.34 b p1 1.57 1.47 b p2 0.31 0.24 8.1 7.9 4.1 3.9 0.30 0.24 4.75 e 1 l 1 0.5 45 l 7.1 6.9 0.85 0.75 l 3 0.7 0.5 dd 1 2.55 0.35 d 2 d 3 (1) max. 0.2 r max. 0.95 l 4 (1) max. 5.45 5.25 e 0.85 0.65 f 3.275 3.075 f 1 1.27 21.4 21.0 h e 6.42 6.32 5.85 h e1 h e2 max. e 1.2 q 1 0.65 0.55 dimensions (mm are the original dimensions) sot637 02-01-18 04-12-10 0 2.5 5 mm scale a e e d 2 f d 3 (1) d 3 (1) h e1 h e2 f 1 l 1 l b p1 d r d 1 l 3 l 4 (1) h e e 1 note 1. terminal dimensions within this zone are uncontrolled to allow for flow of plastic between and besides the leads. l 2 b p b p2 c 1234 5 q 1 q 1 a a sot637 plastic single-ended multi-chip package; 6 interconnections; 5 in-line leads sensor die position * centre of reading point b a view a-b a 0.4 va
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 29 of 33 nxp semiconductors kma200 programmable angle sensor 19. handling information dimensions in mm (1) no bending allowed (2) plastic body and interface plastic body - leads: application of bending forces not allowed fig 14. bending recommendation 006aaa246 r 0.25 min r 0.25 min 0.7 (1) 0.7 (1) 0.7 (1) (2) (2)
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 30 of 33 nxp semiconductors kma200 programmable angle sensor 20. revision history table 15. revision history document id release date data sheet status change notice supersedes kma200_8 20111207 product data sheet pcn 201106032f01 kma200_7 modifications: ? section 16 ? terminals ? : lead finish dimensions changed kma200_7 20080718 product data sheet - kma200_6 modifications: ? section 16: the lead finish thickness has been changed kma200_6 20070102 product data sheet - kma200_5 kma200_5 20050816 product data sheet - kma200_4 kma200_4 20020325 objective specification - kma200_3 kma200_3 20010620 objective specification - kma200_2 kma200_2 20000920 objective specification - kma200_1 kma200_1 20000907 objective specification - -
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 31 of 33 nxp semiconductors kma200 programmable angle sensor 21. legal information 21.1 data sheet status [1] please consult the most recently issued document before initiating or completing a design. [2] the term ?short data sheet? is explained in section ?definitions?. [3] the product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple device s. the latest product status information is available on the internet at url http://www.nxp.com . 21.2 definitions draft ? the document is a draft versi on only. the content is still under internal review and subject to formal approval, which may result in modifications or additions. nxp semiconductors does not give any representations or warranties as to the accuracy or completeness of information included herein and shall hav e no liability for the consequences of use of such information. short data sheet ? a short data sheet is an extract from a full data sheet with the same product type number(s) and title. a short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. for detailed and full information see the relevant full data sheet, which is available on request vi a the local nxp semiconductors sales office. in case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail. product specification ? the information and data provided in a product data sheet shall define the specification of the product as agreed between nxp semiconductors and its customer , unless nxp semiconductors and customer have explicitly agreed otherwis e in writing. in no event however, shall an agreement be valid in which the nxp semiconductors product is deemed to offer functions and qualities beyond those described in the product data sheet. 21.3 disclaimers limited warranty and liability ? information in this document is believed to be accurate and reliable. however, nxp semiconductors does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. in no event shall nxp semiconductors be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation - lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. notwithstanding any damages that customer might incur for any reason whatsoever, nxp semiconductors? aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the terms and conditions of commercial sale of nxp semiconductors. right to make changes ? nxp semiconductors reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. this document supersedes and replaces all information supplied prior to the publication hereof. suitability for use in automotive applications ? this nxp semiconductors product has been qua lified for use in automotive applications. unless otherwise agreed in wr iting, the product is not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical systems or equipment, nor in applications where failure or malfunction of an nxp semiconductors product can reasonably be expected to result in personal injury, death or severe property or environmental damage. nxp semiconductors accepts no liability for inclusion and/or use of nxp semiconductors products in such equipment or applications and therefore such inclusion and/or use is at the customer's own risk. applications ? applications that are described herein for any of these products are for illustrative purpos es only. nxp semiconductors makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. customers are responsible for the design and operation of their applications and products using nxp semiconductors products, and nxp semiconductors accepts no liability for any assistance with applications or customer product design. it is customer?s sole responsibility to determine whether the nxp semiconductors product is suitable and fit for the customer?s applications and products planned, as well as fo r the planned application and use of customer?s third party customer(s). customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products. nxp semiconductors does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer?s applications or products, or the application or use by customer?s third party customer(s). customer is responsible for doing all necessary testing for the customer?s applic ations and products using nxp semiconductors products in order to av oid a default of the applications and the products or of the application or use by customer?s third party customer(s). nxp does not accept any liability in this respect. limiting values ? stress above one or more limiting values (as defined in the absolute maximum ratings system of iec 60134) will cause permanent damage to the device. limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the recommended operating conditions section (if present) or the characteristics sections of this document is not warranted. constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device. terms and conditions of commercial sale ? nxp semiconductors products are sold subject to the gener al terms and conditions of commercial sale, as published at http://www.nxp.com/profile/terms , unless otherwise agreed in a valid written individual agreement. in case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. nxp semiconductors hereby expressly objects to applying the customer?s general terms and conditions with regard to the purchase of nxp semiconducto rs products by customer. no offer to sell or license ? nothing in this document may be interpreted or construed as an offer to sell products t hat is open for acceptance or the grant, conveyance or implication of any lic ense under any copyrights, patents or other industrial or intellectual property rights. document status [1] [2] product status [3] definition objective [short] data sheet development this document contains data from the objecti ve specification for product development. preliminary [short] data sheet qualification this document contains data from the preliminary specification. product [short] data sheet production this document contains the product specification.
kma200 all information provided in this document is subject to legal disclaimers. ? nxp b.v. 2011. all rights reserved. product data sheet rev. 8 ? 7 december 2011 32 of 33 nxp semiconductors kma200 programmable angle sensor export control ? this document as well as the item(s) described herein may be subject to export control regu lations. export might require a prior authorization from competent authorities. quick reference data ? the quick reference data is an extract of the product data given in the limiting values and characteristics sections of this document, and as such is not comple te, exhaustive or legally binding. 21.4 trademarks notice: all referenced brands, produc t names, service names and trademarks are the property of their respective owners. 22. contact information for more information, please visit: http://www.nxp.com for sales office addresses, please send an email to: salesaddresses@nxp.com
nxp semiconductors kma200 programmable angle sensor ? nxp b.v. 2011. all rights reserved. for more information, please visit: http://www.nxp.com for sales office addresses, please se nd an email to: salesaddresses@nxp.com date of release: 7 december 2011 document identifier: kma200 please be aware that important notices concerning this document and the product(s) described herein, have been included in section ?legal information?. 23. contents 1 product profile . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 general description . . . . . . . . . . . . . . . . . . . . . 1 1.2 features and benefits . . . . . . . . . . . . . . . . . . . . 1 1.3 quick reference data . . . . . . . . . . . . . . . . . . . . 2 2 pinning information . . . . . . . . . . . . . . . . . . . . . . 2 3 ordering information . . . . . . . . . . . . . . . . . . . . . 2 4 functional diagram . . . . . . . . . . . . . . . . . . . . . . 3 5 functional description . . . . . . . . . . . . . . . . . . . 4 6 diagnostic features . . . . . . . . . . . . . . . . . . . . . . 5 7 outputs of kma200 . . . . . . . . . . . . . . . . . . . . . . 8 8 digital output (spi). . . . . . . . . . . . . . . . . . . . . . 11 9 limiting values. . . . . . . . . . . . . . . . . . . . . . . . . 12 10 characteristics . . . . . . . . . . . . . . . . . . . . . . . . . 13 11 error codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 12 definition of errors. . . . . . . . . . . . . . . . . . . . . . 18 12.1 general . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 12.2 linearity error . . . . . . . . . . . . . . . . . . . . . . . . . 18 12.3 temperature drift. . . . . . . . . . . . . . . . . . . . . . . 19 12.4 microlinearity . . . . . . . . . . . . . . . . . . . . . . . . . 20 12.5 hysteresis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 13 programming . . . . . . . . . . . . . . . . . . . . . . . . . . 21 13.1 normal operation mode . . . . . . . . . . . . . . . . . 21 13.2 command mode . . . . . . . . . . . . . . . . . . . . . . . 22 13.3 notes to the programming . . . . . . . . . . . . . . . 22 13.4 write ram (0nh), read ram (1nh) . . . . . . . . . 23 13.5 calculate crc-16 and program eeprom (30h). . . . . . . . . . . . . . . . . . . . . . . . 23 14 electromagnetic interference (emi) . . . . . . . . 26 14.1 emission (cispr 25) . . . . . . . . . . . . . . . . . . . 26 14.2 radiated disturbances (iso 11452-2, iso 11452-5) . . . . . . . . . . . . . . . . . . . . . . . . . 26 14.3 transients - pulses (iso 7637-1, iso 7637-3) . . . . . . . . . . . . . . . 26 15 electrostatic discharge (esd) . . . . . . . . . . . . 26 15.1 human body model . . . . . . . . . . . . . . . . . . . . 26 15.2 machine model . . . . . . . . . . . . . . . . . . . . . . . . 26 16 terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 17 marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 18 package outline . . . . . . . . . . . . . . . . . . . . . . . . 28 19 handling information. . . . . . . . . . . . . . . . . . . . 29 20 revision history . . . . . . . . . . . . . . . . . . . . . . . . 30 21 legal information. . . . . . . . . . . . . . . . . . . . . . . 31 21.1 data sheet status . . . . . . . . . . . . . . . . . . . . . . 31 21.2 definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 21.3 disclaimers . . . . . . . . . . . . . . . . . . . . . . . . . . 31 21.4 trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . 32 22 contact information . . . . . . . . . . . . . . . . . . . . 32 23 contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33


▲Up To Search▲   

 
Price & Availability of KMA20011

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X